Fluke 376 FC

TRUE-RMS CLAMP METER

DAILY RATES
Cost per Day $25.00 $15.00 $10.00 $6.00
Duration (days) 1-7 8-14 15-29 30
TYPICAL HIRE PERIODS
Cost $175.00 $210.00 $290.00 $180.00
Duration 7 Days 14 Days 29 Days 30 Days
Committing to 3, 6 or 12 months?
Contact us on 1300 623 605 for fantastic long term hire rates.

Product overview: Fluke 376 FC True-RMS Clamp Meter with iFlex

The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial
and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable
you to log, trend and monitor measurements while remaining safely away from the arc flash zone through
Bluetooth connectivity.

Find the cause of difficult problems

The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals,
such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses
proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as
the circuit protection sees it.

Measure:

  • Voltage to 1000 V AC or DC
  • Resistance to 60 kΩ with continuity detection
  • Min, max, average, and inrush recording to capture variations automatically
  • 500 mV DC measurement range to interface with other accessories
  • 1000 ÎĽF capacitance measurement
  • Work safely and conveniently
  • The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest
    possible protection in a test tool.

The included 18-inch or 36-inch iFlex flexible current probe provides easier access to large conductors in
tight spaces. The flexible probe:

  • Expands the measurement range to 2500 A AC
  • Allows frequency measurement to 500 Hz with body jaw and iFlex

Specifications: Fluke 376 FC True-RMS Clamp Meter with iFlex

General Specifications
AC Current via Jaw
Range 999.9 A
Resolution  0.1 A
Accuracy  2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz) 3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current
Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Flexible current probe
  i2500-10 Flex 0-18 Flex i2500-36 Flex
A      
Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm) 4.8 in (122.2 mm)
Error ±0.5 % ±0.5 % ±0.5 %
B      
Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm) 5.3 in (133.6 mm)
Error ±1.0 % ±1.0 % ±1.0 %
C      
Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm) 5.8 in (147.6 mm)
Error ±2.0 % ±2.0 % ±2.0 %
Measurement uncertainty assumes centralized
primary conductor at
optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits
AC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1% ±5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ±5 digits
Frequency via Jaw
Range 5.0 Hz to 500.0 Hz
Resolution  0.1 Hz
Accuracy  0.5% ±5 digits
Trigger level  5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Frequency via Flexible Current
Probe
Range 5.0 Hz to 500.0 Hz
Resolution  0.1 Hz
Accuracy  0.5% ±5 digits
Trigger level  5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance
Range 60 kΩ
Resolution 0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ)
Accuracy 1% ±5 digits
Capacitance
Range 1000 ÎĽF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth
ground
1000 V
Batteries 2 AA, NEDA 15A, IEC LR6
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity

non-condensing (< 10°C)
≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude 2000 m
Storage altitude 12,000 m
Size (L x W x H) 249 x 85 x 45 mm
Weight 395 g
Jaw opening 34 mm
Flexible current probe diameter 7.5 mm
Flexible current probe cable length
(head to
electronics
connector)
1.8 m
Safety IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V
   
IP rating IEC 60529: IP30, non-operating
Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility
(EMC)
International IEC 61326-1: Portable, Electromagnetic
Environment, IEC
61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated
and/or uses
conductively-coupled radio frequency energy that is necessary for the internal function of the
equipment itself.
Class A: Equipment is suitable for use in all
establishments
other than domestic and those directly connected to a low-voltage power supply network that supplies
buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic
compatibility in other environments due to conducted and radiated disturbances. Emissions that
exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC) Class A Equipment (Industrial Broadcasting &
Communication
Equipment)
Class A: Equipment meets requirements for
industrial
electromagnetic wave equipment and the seller or user should take notice of it. This equipment is
intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered
an exempt device
per clause 15.103.
Temperature coefficients Add 0.1 x specified accuracy for each degree C
above 28 °C or
below 18 °C

Fluke 376 FC Data Sheet

Download