Omicron Franeo 800

Frequency Response Analyzer

DAILY RATES
Cost per Day $310.00 $279.00 $232.50 $195.00
Duration (days) 1-7 8-14 15-29 30
TYPICAL HIRE PERIODS
Cost $2,170.00 $3,906.00 $6,742.50 $5,850.00
Duration 7 Days 14 Days 29 Days 30 Days
Committing to 3, 6 or 12 months?
Contact us on 1300 623 605 for fantastic long term hire rates.

More than a test device

 

FRANEO 800 was developed for testing the mechanical and electrical integrity of power transformers after
transportation or exposure to high fault currents. It uses the sweep frequency response analysis (SFRA) principle
and
measures the electrical transfer function over a wide range of frequencies. With our FRANEO 800 you can improve your
transformer reliability, reduce maintenance costs and prevent expensive failures.

Small details make a big difference

 

FRANEO 800’s overall measurement principle is based on a comparison of an actual measurement and its fingerprint in
order to allow detection of deviations. Therefore, it is vital that the measurement becomes reproducible which
substantially depends on the connection technique used.
The specially designed clamps and wide flat braids guarantee a reliable test setup, making FRANEO 800 less sensitive
to influences from its surroundings and also easier to use.

Simplified testing

 

FRANEO 800 is operated with the Primary Test Manager™ (PTM) software, the ideal solution for diagnostic testing,
condition assessment and easy data management.
PTM automatically generates test plans based on the nameplate data and in accordance with international standards.
Existing results can be easily imported in order to ensure a flexible, device-independent comparison. In addition,
PTM
offers automatic result assessment and smart features, such as the visualization of typical influences for
deviations.

Key features

  • Extremely small and compact device guarantees optimum usability
  • Innovative connection technique ensures high level of reproducibility
  • Short measurement times due to the intelligent sweep algorithm
  • Highest dynamic range in SFRA testing industry (> 150 dB)
  • Fully compliant with the IEC 60076-18 and IEEE C57.149 standards

Applications

 

FRANEO 800 can be used for transformer testing, after:

  • a short-circuit event
  • before and after transport
  • an occurrence of high transient fault currents
  • a significant change in the monitored values (for example, combustible gases) or a safety shutdown

The following tests can also be performed:

  • Routine transformer condition measurement
  • Verification of unusual events determined during conventional testing

Omicron Franeo 800 Brochure